Ricoh 810081108120 code SC595 appears

Visitor 286 0
Fault diagnosis>Repair call 501-595>SC500 (Engine: Paper Transport 3: Feed, Double sided, Transfer, Fixing) (Pg. 1162)
Correct the following SC595-00 (TDCU hardware error) explanation.
SC NumberLevelError Name/Error Condition/Main Reason/Solution
SC595-00DTDCU hardware error
TDCU command notification
STM malfunction, brush click malfunction, wiring harness not connected
Replace IOB, wiring harness, and motor. TDCU is installed on the IOB board and cannot be replaced separately

Tags: #595 #8110 #8120 #8100