Ricoh 8200 Report Error Code SC466-00

Come back soon. 424 0

Reported fault code SC466-00 for repair 8200, asked the customer what actions they have taken recently, and the customer reported that they changed 2 revolutions a few days ago and cleaned the drum. Check the fault symptoms described in the manual, with a focus on inspecting the area around 2 revolutions.

Maintenance ideas:

1. Check if the protruding patch of the 2-turn component is pressed against the ITB rack (without deformation) and if replacing the 2-turn component is unsuccessful.

2. Check if the ITB guide board is deformed and collides with the ITB separation cam. If the guide board is not deformed, remove it, clean the in-situ sensor, and still report 466-00 when turned on.

3. Attempted to rotate the PTR separation motor belt, but found that the belt motor could not rotate. Pulled out the drawer and tried pressing both sides of the 2-turn component, but found that the 2-turn component could not sink.

Problem Analysis:

Due to the inability of the 2-turn component to sink, the PTR separation cam cannot rotate, triggering the in-situ sensor alarm SC466-00. Dismantle the 2-turn component and inspect the lifting frames on both sides below. It was found that a plastic buckle of the 2-turn drive gear was pressing against the lifting frame, causing the 2-turn component to be unable to sink and separate, resulting in a fault code. After removal, the printer was tested and printed normally upon startup.

Reflection: The falling of the 2-turn plastic clip also confirms the customer's negligence in replacing the 2-turn component and the error caused by non-standard operation. Explain to the customer and emphasize again the importance of standardized operation to avoid the occurrence of some malfunctions. Normally, attention should also be paid to the hygiene and cleanliness of the rack below the 2nd wheel, which may cause similar malfunctions.

Tags: #SC466 #secondary transfer #8300 #8200 #8100