Ricoh C5200S E24B server cannot be connected, the model changes to MF C8003

Come back soon. 357 0

Symptom: Unable to connect to E42B service for printing, GW printing is normal.


Reason:

Check the host SP code settings, check the connection with the server, but still cannot connect after reinstalling the server system. The test server can be used normally when connected to other hosts. Replacing the host gigabit network card, BICU board, controller board, hard drive, and IOB board with other machines for testing can connect to the server and print normally. When printing the SMC table, it was found that the model had changed to MP 8003, but the machine number had not changed

The analysis machine model has been changed to C8003, and all board components tested are normal. Inquire with the customer to learn that there have been instances of power outages and tripping before the machine malfunctioned, but the NVRAM data imported for backup still fails. Because the NVRAM chip of the testing machine was installed during the testing of the controller board and BICU board. Suspected problem with NVRAM chip, order D2589590


After the chip arrives, strictly follow the NVRAM replacement steps in the maintenance manual's replacement and adjustment section. During the process of downloading old NVRAM data from the SD card to the new NVRAM chip in SP5-825-001 (NVRAM data download), there were always errors and failures, and the operation could not be completed after multiple attempts.


Solution:

Follow the maintenance manual to complete the subsequent steps and restart the machine. The machine started normally and the model in the SMC table was restored to ProC5200S. Importing NVRAM into SP5825 again still failed. View SP5-193-001 (External Controller Information Setting) Current 0 → Change to 1

SP5-895-001 (Application Invalid/Printer) Current 0 → changed to 1. After restarting again, the server connected and printed normally. SP5825 successfully imported NVRAM again.

The reason for the inability to import NVRAM data before analysis should be that the machine was changed to GW printing while waiting for parts, and the selected NVRAM data for import was the data when connecting E-24B during new installation (due to chip issues, the NVRAM data before replacing the chip was not exported according to the steps in the maintenance manual), resulting in inconsistent settings and conflicting data, leading to import failure.


Attention: After replacing the NVRAM chip, reset the total counter value to "0". Remember to save the printed sheet data.

Tags: #Server #E42B #C5300 #C5200 #C5100

Leave a comment