Ricoh IMC2000 color output when the image has a magenta background

Come back soon. 342 0

Symptoms:

When a M C2000 machine outputs color files (printing/copying), there is a magenta background color overlay (as shown in Figure 1), and the image is normal when outputting black and white.


Maintenance process:

1. Installing the magenta PCDU unit of the faulty machine onto another machine for testing resulted in a shallow image without any background color (Figure 2);

2. Key inspection was conducted on the charging and bias terminals corresponding to the machine's relative position behind the magenta PCDU unit, and no abnormalities were found;

3. Firstly, consider replacing the charging/bias high-voltage board and transfer high-voltage board for testing, but the fault persists;

3. After replacing the BICU board, the fault was resolved.


Solution:

Replace the BICU board.

Tags: #Magenta #Drum set #Red background gray #C2000 #C3500