Symptoms:
After the new machine is installed, the print counter page is normal, the copy counter page (the long side is the first-end paper feed), the copy is about 60mm wide along the lower edge of the paper, the power is turned off and restarted, and the fault remains (see the figure below, the machine number has been blurred, and this part of the image has nothing to do with the case fault):
Analyze and resolve:
1. Since the printing counter page image is normal, the reason for excluding the parts around the drum;
2. Copy with two different ways of document feeder and pressure plate, the failure phenomenon is exactly the same;
3. Observe the scanning head assembly and optical cavity, no dirt or other abnormalities are found;
4. Check the connection harness between the MPU and the scanning head, the connection is firm, and no abnormality is found;
5. Replace the scanning head assembly and troubleshoot.
Solution:
Replace the scan head assembly and troubleshoot.
(Red part in the picture below, part number: D2451631)
Note:
The part number of the scanning head assembly of MP2014AD model is different from that of MP2014 and MP2014D models. Be careful not to use it incorrectly!
Tags: #2014AD #2014 #Black line #scanning head #Connecting wire harness