Symptoms: The customer reported that the machine has been unstable recently and the SC563 code jumps several times in the morning. After checking the manual, the fault code description is as follows. Although it can continue to be used after resetting, it affects the customer's production efficiency.
Reason:
SC563-00 Error Name Software High Temperature Error (Sensor 5): Fixing Temperature Sensor (Pressure Roller)
Mode A
Continuous detection of abnormal high temperatures due to error conditions.
main reason
The fixing temperature sensor (pressure roller) (SEN80) is faulty.
AC control board malfunction.
IOB is defective.
The wiring between the AC control board and IOB is poor.
Solution:
*If a fixing SC occurs during the inspection, perform a "fixing SC reset" (SP5-810-001) in SP mode each time an SC occurs, and then restart the main power supply.
1. Replace the wires (as well as the fixing temperature sensor (pressure roller)).
2. Replace the AC control board.
3. Replace IOB.
4. Replace the wires between the AC control board and IOB.
Maintenance ideas
After replacing the fixing roller due to the expiration of the PM lifespan, the malfunction began to occur with a low frequency at the beginning. Therefore, special attention should be paid to checking the assembly, ensuring that the assembly is normal, the bearings are normal, the gear wear is normal, the gears are lubricated, and the fault persists.
2. The multimeter measures the thermostat and cleaning sensor, and the visual inspection is normal. However, when the printing volume increases, the code will jump
3. Upgrading firmware is ineffective, improving the ventilation environment for fixing is ineffective, and checking the SP code indicates that the sensor is responding normally. The fixing lamp tube is normal
Although the malfunction did not cause a complete shutdown, the customer's patience was limited. So I prepared to disassemble and assemble the pressure roller again, replace the new pressure roller, and install the old pressure roller. At this time, I found that the wires of the temperature sensor were very thin, and it was normal to see that the rubber was not damaged. The replacement pressure roller had not been moved. With a trial and error attitude, the code has not jumped again for 2 months after using 3M high-temperature resistant insulation tape to strengthen the insulation treatment between the wire and the metal frame that may come into contact.
Solution
After analysis and sorting of ideas, it is believed that replacing this sensor may also have the same effect. But in the absence of sensors on site. Insulation can be done well, but it should be due to the deterioration of the insulation effect of the rubber after being heated, resulting in abnormal sensor detection. Perform key insulation at the red circle.
If you want to replace the sensor, sensor number: D1795387