Symptoms: The device displays error SC621-00, and also indicates that the waste toner bottle is full, the toner cartridge cover is not closed, and the paper tray is empty.
Reason:
1. The power supply of the pager is not connected correctly
2. Pager and host connection plug bad
3. Poor power supply of pager
4. Other faults cause
Solution: After arriving at the customer site, first check the power connection of the pager and whether the plug connected to the host is intact. Plug and unplug the power plug and the plug connected to the host again, and the startup fault remains. Shut down, unplug the power supply of the pager, and the multimeter tests that the incoming 220V is normal. Unplug the plug between the pager and the host, and the fault remains after starting up. It feels strange at this point. If the peripheral equipment is disconnected under normal conditions, the host can start normally. Check the description of the fault in the maintenance manual again.
According to the above description, the PSU-C two fuse fuses will also cause the fault to occur. Remove the PSU-C plate, measure two insurance is OK, and measure several other insurance is no problem. View the function of each board
The PSU-C is still the most suspected. The board is removed and taken to another customer for computer testing. The fault reappears. It is determined that this power board is really bad. When the original board was disassembled and replaced, the two boards were not replaced at the same time, resulting in damage to the customer's PSU-C board. As the warehouse was out of stock, three PSU and one AC power board were urgently borrowed from Caohejing. The next day, the power supply and output of the PSU-C were measured at startup. It was found that there was 220V power supply, but there were no 5V and 24V outputs. After replacing the PSU-C, the equipment was normal. Go to the customer who had this fault before and measure the fault PSU-C. There is no power supply or output. Remove the AC power board and measure several ceramic fuses on the AC, one of which is fused. Measure the customer's on-site power supply, the fire-to-ground voltage is 163V, the zero-to-ground voltage is 56V, and the zero-to-fire voltage is 220V. This voltage is very abnormal. Disassemble the power supply socket, there is only zero live wire and no ground wire. Tell the customer to make a ground wire. After the ground wire is connected, replace the faulty PSU-C and AC power board and the machine will return to normal.
Maintenance experience:
Based on this maintenance, the high probability of failure is due to the non-standard power supply on the customer's site, resulting in damage to the AC power supply board and the PSU-C power supply board. Because this customer equipment has been used for more than 5 years, it did not take into account the irregular power supply on the customer's site and did not focus on checking the customer's power supply. The maintenance process is not rigorous enough, resulting in the loss of an additional PSU-C plate, later replacement or to replace together, do not replace separately.
Tags: #SC621 #8100 #Power board #8200 #Waste powder bottle full