Ricoh MP650375039003SP copying process report code SC300-00
1. MP6503SP maintenance manual, SC300-00 code reference solution is shown in the table below
2. Check the connectors, wiring harness, and corona power supply group of the charging corona unit according to the above table, but it is invalid. [kkpay=6]3. Further replacement of the charging corona unit and AC drive board, the fault persists. The following diagram, from left to right, is: 1. Corona power pack 2. AC drive board 3. Charging corona unit
4. Setting aside the solution to the SC300-00 code in the maintenance manual, let's start with the fault sample. Firstly, replace the drum unit, and as a result, the fault was eliminated. 5. Based on this result analysis, it can be concluded that in the case of abnormal drum potential, it can also trigger a code of high feedback voltage in the charging corona unit. Solution Replace OPC drum. Note: This case is an isolated case, and it is rare for the phenomenon to occur due to the photosensitive drum. Most of the fault causes are concentrated in the charging unit, high-voltage board, power board, drum bracket (upper part), etc.[/kkpay] |
Tags: #300 #6503 #7503 #Charging #Power board