White bars appear at both ends of Ricoh DD3344C image

Visitor 292 0
Symptoms
There is a blank space of about 3 centimeters on both sides of the DD3344C plate making image (machine operation side and back cover direction), and this situation also occurs in the SP8-10 printed test pattern.

Cause analysis
1. Check that the centering of the paper table and the setting of the paper table side baffle are correct.
2. No abnormalities were found during the inspection of the plate paper transmission.
3. Replace the MPU board and thermal head for testing, but the fault persists.
4. Upon inspection, it was found that the insertion and removal of the drum were not smooth, and there was wear on the drum teeth and main gear. The drum was replaced and tested, and the fault was eliminated.
5. Replace the main gear and drum teeth.

Tags: #3344 #White slip #gear #Drum