Ricoh AFMP2852 has a gray background when copying

Visitor 354 0
symptom:
When using the manuscript table and feeder for copying, there is bottom dust appearing. A4 paper runs on the long side, with bottom dust appearing on the near side, normal on the far side, and normal printing.

Diagnostic process:
Due to normal printing, it can be inferred that the problem occurred in the scanning section. The malfunction persists despite cleaning the optical reflector and replacing the SBU unit. After inspection, it was found that the left front corner of the scanning table had sunk, causing deformation of the manuscript table and resulting in the above-mentioned malfunction when scanning the original manuscript.

Solution:
Restore the scanning table position and make normal copies.

Tags: #bottom ash #2852 #3352