Symptoms After the installation of the new machine, the plate making and printing test showed that the A4 format scanning plate making was normal, but there was a large black area at the end of the A3 format plate making process Maintenance analysis process 1. The sample image of the thermal head test using HELP-030 output is good (Figure 2), indicating that the fault should be caused by the optical unit. 2. Check the operation of the optical first and second scanning frames, and no abnormalities were found in the first, second, and third mirrors. 3. Clean the lens components and CCD surface on the SBU board, but the fault persists. 4. Attempt to adjust the 3 floating screws in the lens assembly (with spring support at the bottom) as shown in Figure 3, and the test image shows significant changes after adjustment. The final adjustment result is normal and the fault has been resolved. Solution: Adjust the three suspension screws of the lens component (in this case, only one in the upper left corner of Figure 3 was adjusted). Note: 1. The adjustment should be factory tuning, and the machine's malfunction is suspected to be caused by improper transportation. 2. When adjusting the suspension screw on site, usually only one can be adjusted to determine the adjustment direction, and there is no need to turn the screw, just add a washer under the nut. [kkpay=5] Link:https://pan.baidu.com/s/1CX5U9Da_NPGDBDSw-q9Ypg Extraction code: zhxn [/kkpay] |
Tags: #5451C #Plate making #Black #Lens assembly #SBU