Symptoms There is an MP W2400 machine that displays SC392 during startup, but cannot be resolved by turning it on or off. Cause of the failure: According to the manual, the explanation for SC392 is as follows: Error in developing bias voltage Possible faulty components: damaged bias terminal, damaged high-voltage connecting wire, poor CGB power supply component Resolution process: 1. Check the bias terminal and high-voltage connection wire, both of which are normal. 2. Replace the CGB power component, but the fault persists. 3. Using a multimeter to measure the CGB component of the faulty machine, it was found that there was no developing bias output. 4. It can be inferred from the P to P diagram that the CGB component is controlled by the MCU. 5. Replace the MCU board, but the fault persists. 6. Checked the+24V output of the MCU and found no voltage output. 7. No abnormalities were found in the connection wires between CGB and MCU during measurement. 8. Upon reviewing the P to P diagram, it was discovered that there are several switches on the+24V circuit of the machine. 9. Upon inspection of these switches, it was found that the trigger plate (number 19 in the figure) of the UPPER Unit switch was not installed correctly. The switch was reinstalled and the fault was resolved. The position of this switch is as follows:
|