Symptoms MPW2401 prints and copies drawings with blurred text, and prints IPU test graphic SP4417-27 (horizontal gray mark) with large white areas (see figure).
Reason Printing unit installation error. Maintenance process 1. First, scan the drawing to the document server, preview the scanned document and find that the image is normal. Exclude the image fault caused by the scanning unit and suspect that the drum area component is causing the fault. When inspecting the drum area, it was found that the protruding ear of the transfer unit (B in the figure) was not correctly installed at the bolt (C in the figure). After reinstalling it correctly, the fault was eliminated.
|