Symptoms Aficio MP W2400 reported SC865 (HDD entry error). After replacing the HDD with a new one, there was no output when printing CAD drawings, and the data light on the LCD panel flickered. During this period, no error codes were reported. Maintenance ideas 1. Is the new HDD installed properly, and are the data cables and other components not installed properly 2. After installation, have SP5-832-1 and SP5-853 been executed 3. Check if SMC report output is normal and replace the IP address of the engineering machine 4. Remove the printer driver and reinstall it Solution 1. Reinstall the hard drive and perform SP5-832-1 (HDD Format - All) to format the new HDD. Execute SP5-853 (Seal Data Download) again to download the inherent seal data from ROM to the hard drive, but the fault persists. 2. The SMC report was printed using SP5-990-1, and the SMC output was normal, but the fault persisted. 3. Print the Windows test page, which can output normally. After eliminating the HDD issue, the fault still persists. 4. Reinstall the HDI driver and troubleshoot. Hint: After replacing the hard drive with a new one, it is recommended to reinstall the print drivers (HDI, PS3, RPCS). After replacing the new hard drive, SP5-832-1 must be executed. |
329
0
Address of this article:https://073868.com/post/3026.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleRicoh W2401, W3601 bad image