Ricoh M2701 Scan to Folder The manuscript table cannot scan the original continuously.

Visitor 342 0
Symptoms
M2701 scans into the folder, and multiple original drafts are scanned through the manuscript table. After scanning the first original, the machine does not place the next original and completes the scanning directly.

Reason
If scanning multiple original documents using a document table, the continuous scanning function in the scanning settings must be turned on. This function is set to off by default, so it is not possible to use the document table to scan multiple original documents.

Solution
1. Press( Left, right Key Settings) Select Scan Settings
2. Select [Continuous Scan] in the scanning settings and set it to [On]
3. After setting up, use the manuscript table to scan multiple original documents, and the machine will display the following prompt
According to the machine's settings, when scanning from the exposure glass, you may see the following image on the display screen.


If you want to scan more original documents, please place the next page of the original document on the exposure glass and press the selection key under [Yes]. Repeat this step until all original documents have been scanned.

Tags: #Scan #Original #2701