The copy image of Ke Mei B287 is ghosted and weak.

Visitor 300 0
<机型>
Bizhub 287

<故障现象>
Bizhub 287 currently has a print run of 2000 copies. When copying a document, there may occasionally be 1 to 2 copies with poor image quality, while other copies are normal; The same malfunction occurred during ADF copying, manuscript table copying, and scanning to the USB drive, and the customer did not connect the printer; After restarting the machine, it returned to normal. After using it for a period of time, the fault will occur again (see the fault sample on the next page)

Original

photocopy<故障对策>

1. Use the mid stop method to check the copy and determine that there is already a ghosting in the image before entering the fixing process, so rule out the problem with the fixing component;
2. Replace IU components (including charging) and conduct pH testing, but the fault persists;
3. After replacing MFPB, the test was conducted for a period of time, and the output images were observed to be normal.


Tags: #Double image #Hair deficiency #Image #Ke Mei #Photocopy