Any MFP with Wide-Area Bonjour enabled may start with a fault code C- E301 (0xC001)

Visitor 375 0
Any MFP with Wide-Area Bonjour enabled may start with a fault code C- E301 (0xC001)
Model bizhub 227,bizhub 287,bizhub 308,bizhub 308e,bizhub 368,bizhub 368e,bizhub 458,bizhub 458e,bizhub 558,bizhub 558e,bizhub 658e,bizhub 758,bizhub C227,bizhub C287,bizhub C308,bizhub C3351,bizhub C368,bizhub C3851,bizhub C458,bizhub C558,bizhub C658,bizhub C659,bizhub C759
1. Problem details:When the following conditions are met, the machine will display fault code C-E301 during startup[Condition]When all three settings are set to the following, a fault code appears-Set [Administrator Settings]>[Network Settings]>[Bonjour Setting]>"ON">[Side Area Bonjour] to "ON"-Set [Administrator Settings]>[Network Settings]>[TCP/IP Settings]>[IPv6 Settings] to "OFF"-Set [Administrator Settings]>[Network Settings]>[TCP/IP Settings]>[IPv6 Settings] to "OFF"2. Model of occurrence:Please refer to the table below for information on the occurrence model and affected versions
Occurrence modelAffected versions
bizhub C759/C659G00-10 and later versions
bizhub C658/C558/C458G00-R9 and later versions
bizhub C368/C308/C258G00-R9 and later versions
bizhub C287/C227G00-R9 and later versions
bizhub C3851/C3351G00-R9 and later versions
bizhub 658e/558e/458eG00-09 and later versions
bizhub 368e/308eG00-09 and later versions
bizhub 558/458G00-R9 and later versions
bizhub 368/308G00-R9 and later versions
bizhub 958/808/758G00-R9 and later versions
bizhub 4752/4052G00-11 and later versions
bizhub 367/287/227G00-R9 and later versions

3. Reproduce Example~Reproduce the environment~Model/firmware: C368/GC1-W4
-Probability of occurrence-100%
~Steps~On the administrator settings, perform the following network settings in order:2. Set [Administrator Settings]>[Network Settings]>[Bonjour Setting]>"ON">[Side Area Bonjour] to "ON"3. Set [Administrator Settings]>[Network Settings]>[TCP/IP Settings]>[IPv6 Settings] to "OFF"4. Set [Administrator Settings]>[Network Settings]>[TCP/IP Settings]>[DSN Server Settings (IPv6)] to any IP address
~Result~Whenever the main power is turned on, fault code C-E301 will appear Additionally, sometimes a restart may occur immediately after setting up step # 1
4. ReasonFirmware defect
5. relevant information(CSES-ID)ERBJTK1900918707
SolutionPlease adopt the following contingency measures until the corresponding firmware is released
[Contingency measures]To avoid the occurrence of fault codes, please make one of the following settings -Set [Side Area Bonjour] to "OFF"-Set [IPv6 Settings] to "ON"-Set all IP addresses in DSN Server Settings (IPv6) to 0