Maintenance process: 1. easy to add carrier for CP105 Since the CP105 model does not have a liquid crystal panel, it is very inconvenient to add a carrier. If the "repair tool" is replaced, the CP105 will temporarily become a CP205 or CP215, and the carrier can be added according to the method of adding a carrier of CP205 or CP215. 1. Replace the "repair tool" s 2. Prepare an empty toner cartridge, pour the carrier into the empty toner cartridge, and then load the cartridge with the carrier into the machine; 3. Enter the diagnostic mode (press and hold the up and down keys, turn on the machine at the same time), the panel displays Service Mode, release the up and down keys, (password twice down key); 4. Press the OK key-down key in turn, and the panel displays Engine Diag; 5. Press OK-down key in turn, and the panel will display Motor Test; 6. Press the OK key, the panel will display "Main Motor" (main motor full speed), press the "OK" key, the machine will turn on yellow and red light, and the motor will not rotate; 7. Press the up key to find "24V ON", and then press the "OK" key, the main motor starts to rotate; 8. Press the up key to find "Yellow Toner Motor", press the "OK" key, and the yellow powder motor starts to rotate. When the powder motor and the main motor rotate at the same time for about 2 minutes, so that all the carriers are added into the developing chamber, press the "menu" key, and the motor stops rotating; 9, other color carrier similar operation process; 10, restart the machine; 11, restore the motherboard. 2. to solve the problem of toner non-recognition of CP105/CP205/CP215 There has been related technical communication before. NVM backup tool can be used for data backup, but a completely normal machine is required every time. If the "repair tool" is used, it may be easier to deal with toner non-recognition failure (except for detecting the contact deformation of toner chip). 1, replace the "repair tool" 2. Turn off, press and hold the up and down buttons of the LCD screen-turn on, the machine is connected to the diagnostic mode, and the password is down twice; Service Mode Engine Diag -- NVM Settings -- Load NVM from ESS--OK -- Panel shows Load NVM from ESS Loaded; 4. Shut down, restart the printer, and eliminate the fault; 5, shutdown, remove the maintenance tools, restore the motherboard. 3. to solve 092-661 fault 1, replace the "repair tool" 2. Turn off, press and hold the up and down buttons of the LCD screen-turn on, the machine is connected to the diagnostic mode, and the password is down twice; Service Mode Engine Diag -- NVM Settings -- Load NVM from ESS--OK -- Panel shows Load NVM from ESS Loaded; 4. Shut down, restart the printer, and the fault is eliminated; if the fault persists, it may be an engine board fault. You need to replace the engine board and try again. The engine board number: 100L98460; 5. Print the "system Settings" test page and check the Current Temperature (current temperature) option. If it is consistent with the current actual temperature, the machine is normal. If there is a big difference with the actual temperature, there may be a hardware failure on the engine board. Please replace the engine board. The engine board number is 100L98460; 6, shutdown, remove maintenance tools, restore the motherboard. 4. to solve 024-340 fault 1, replace the "repair tool" 2. Turn off, press and hold the up and down buttons of the LCD screen-turn on, the machine is connected to the diagnostic mode, and the password is down twice; Service Mode Engine Diag -- NVM Settings -- Load NVM from ESS--OK -- Panel shows Load NVM from ESS Loaded; 4. Shut down, restart the printer, and the fault is eliminated; if the fault persists, it may be an engine board fault. You need to replace the engine board and try again. The engine board number: 100L98460; 5, shutdown, remove the maintenance tools, restore the motherboard. Note: In most cases, 024-340 fault is easy to occur after replacing the engine board, which can be repaired after Load NVM from ESS is executed. Precautions: 1. When executing "Load NVM from ESS, if it occurs for a very long time (more than 5 minutes), please consider the possibility of failure of the relevant cable and engine board; 2. Please ensure the correctness of the internal data of the "Repair Tool" and never execute the "Save NVM to ESS" option on a faulty machine. |
295
0
Address of this article:https://073868.com/post/2281.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleXerox DPCP105b/205 Carrier Method