Ricoh C7100s image around uneven concentration: 40mm spacing

Visitor 286 0
Due to the charging difference between the front and rear of the drum, the toner concentration is uneven on the left and right sides of the image, with a spacing of 40 mm.Easy to happen:
  • Winter morning when the first print


Solution
  • Set the SP2-109-003 (Test Pattern) to "12 (Independent Pattern 2 dot)".
  • Print test chart.
  • Is the image uneven on the left and right? Yes: Go to the next step.
    No: complete
  • Is the spacing where the problem occurs 40mm? Yes: Go to the next step.
    No: Refer to other solutions.
  • Perform "Process Control (SP3-011-001)".
    • Generally, process control is performed when the machine is turned on for the first time. However, in a low temperature and low humidity environment, the AC charging bias adjustment may not be completed. Therefore, it is necessary to manually perform the process control again.
  • Print the target image.
  • Is the printed image acceptable? Yes: Done
    No: Go to the next step.
  • Increase the room temperature (guide temperature 20°C or above) and wait at least 30 minutes.
    • Increasing the room temperature can control the increase in the resistance of the charging roller and solve the problem of insufficient drum charging.
  • Print the target image.
  • Is the print image acceptable? Yes: Done
    No: Go to the next step.
  • Turn on the anticoagulant heater.
    • Turning on the anticoagulation heater can ensure the temperature inside the machine when the main engine is turned off.
  • Print the target image.
  • Is the printed image acceptable? Yes: Done
    No: Go to the next step.
  • Replace the charging unit.
    • If the above 5 to 7 steps do not solve the problem, if you need a quick response, replace the charging power supply.