Ricoh Pro8210 printing 80 grams of offset paper is normal, but 200 grams of thick paper is seriously skewed.

Visitor 297 0
Symptom: 8210 prints 80 grams of double adhesive paper normally, but prints 200 grams or more of leather paper with severe skewness.

Reason: The screws of the alignment unit mechanism are loose, causing uneven pressure on both sides when the paper passes through the alignment mechanism.

Solution:
1. According to customer feedback, 80 grams of double adhesive paper are mostly used for printing on a regular basis. Occasionally printing A3 leather paper weighing over 200 grams may result in severe horizontal skew. However, both A3 and A4 double-sided adhesive paper were tested and printed normally.
2. The customer habitually prints 200 grams of A3 leather paper in large capacity paper boxes. On site testing showed that the hand fed paper boxes, as well as large capacity paper boxes 4, 5, and 6, all had the same malfunction.
3. Check if there are any foreign objects such as shredded paper in the paper path and alignment unit mechanism of the large capacity paper box. All checks are normal.
4. Put 200 grams of A3 leather paper into the main machine paper box for testing and printing. Although the paper jam is severe, occasionally one sheet comes out with serious skewness. The fault should be located in the alignment unit mechanism.
5. Focus on investigating the corresponding institutions. Upon inspection, it was found that one side of the screw on the important position of the alignment roller was loose. As shown in the following figure:



6. After re fixing the screws, test and print 200 grams of A3 leather paper, and the skew disappears.

Summary: Printing thin paper is normal, while printing thick paper is skewed. The reason is that printing thin paper requires less pressure and can pass smoothly. Printing thick paper requires high pressure, and the pressure on both sides is uneven, resulting in skewness. The cause of this malfunction may have been due to negligence during previous maintenance processes, where the screw was not tightened. However, this screw happened to be fixed on the moving mechanism and gradually loosened during repeated movements, leading to this malfunction. We must learn from our mistakes seriously in the future

Tags: #8210 #Leather Paper Skew #8200 #8220 #para unit