An IM C6500 machine has encountered an SC370-03 fault; this code can be cleared by turning the machine off and on again. After outputting several images in a row, it appears again. Maintenance process 1. Use SP7403 to check the SC history and find that the recent history is full of SC370-03 fault codes; 2. After executing SP3011 manual process control, check the execution result with SP3012 to show "21212121", and check "21:Vsg adjustment error" through the maintenance manual "; 3. Use SP3320 to manually perform Vsg adjustment of ID sensor and then SP3323 check and adjust the result to display "2"; 4. Since the equipment has used more than 1 million pieces of relevant PM parts that have not been replaced, the relevant PM parts that affect Vsg detection are replaced first: ITB unit and ITB cleaning unit. As a result, the fault has not been eliminated; [kkpay=4]5. Replace the ID sensor itself and troubleshoot. Solution: Replacing ID sensor (part number: marked in red on D0CN6100 part drawing) Note: Most of the similar problems encountered in daily maintenance are due to the aging of PM parts that were not replaced in a timely manner, and the probability of ID sensor damage in this case is very small.[/kkpay] |
343
0
Address of this article:https://073868.com/post/1258.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleRicoh IMC6500 boot code SC536-02