Symptoms: An M 2701 machine produces incomplete images when copying using a document feeder.
Maintenance process: 1. Copying images using the draft table method is normal; 2. The size detection of the original manuscript in this model's document feeder is carried out by: Original width sensor - detects width; Paper feeder alignment sensor - detects the length of the plaintiff. 3. The alignment sensor of the cleaning feeder is still malfunctioning; 4. Troubleshooting after replacing the original width sensor of the document feeder.
Solution: Replace the original width sensor (part number: AW500039). Note: The width sensor of the original manuscript feeder of this model adopts a "disc type", please pay attention to the correct position when installing: 1. Firstly, retract the side panel of the original manuscript tray to the narrowest position; 2. Align the small holes on the disc with the small holes on the drive rack; |