Symptoms SC531-00。 Maintenance process 1. A MP2014en startup report SC531-00 was found, and it was confirmed in the maintenance manual that the exhaust fan was faulty.
2. First, replace the exhaust fan directly and then turn it on for testing. The fault still persists. Therefore, the fan and its connecting harness are located at the fixing outlet position, so it is suspected that the harness may also be damaged due to prolonged high temperature. After checking the dot diagram, use a multimeter to measure the conductivity and short/open circuit of the fan connecting harness. 3. Therefore, there is a short interface in the wiring harness from the fan to the MPU's CN217 interface. Therefore, the conductivity was measured separately from the fan to the short interface, from the short interface to CN217, and from the fan to CN217, and the measurement results were all normal. 4. Upon disassembling the wiring harness, it was discovered that there was insulation wrapping in the middle. Therefore, upon inspection, it was found that the wiring harness was broken and had been reconnected, leading to suspicion of signal interference between the wiring harnesses.
5. After replacing this wiring harness, troubleshoot the issue. It was determined that the wiring harness connecting the short interface to the MPU was damaged and caused the fault. After installing the original fan and testing it on, SC531-00 was reported again. The fan was removed again for inspection and measured with a multimeter. It was found that two of the three wires of the fan were short circuited, which was different from the normal fan measurement result. Normally, all three wires were not connected and the resistance value could not be measured. Confirm that the exhaust fan is also damaged causing the malfunction. Solution After replacing the exhaust fan and its connecting harness to the MPU, the fault was resolved. Note: This fault is also provided to everyone. When measuring the conductivity of the wiring harness, try to use the resistance value to determine the conductivity situation as much as possible to avoid misjudgment. |
Tags: #SC531 #2014 #2014en #Exhaust fan