SymptomsM2701When copying on the original manuscript table glass, the image should be parallel to the sub scanning direction and along the edge of the front end1CMLeft and right black bars,A3andA4The phenomenon of scanning and copying the original manuscript is the same. Check that the image is not skewed, and the magnification is not enlarged or reduced.
Solution SP4-010-001Adjust the alignment of the scanning tip toCISWhen scanning units, the starting position should be towards the front.
|
Tags: #Glass photocopying #Black stripe #2701 #2700 #Not skewed