Symptoms IMC3500 the machine, the screen only shows "direct connection" after starting up, no other function icons. Diagnostic process 1) After investigation, there are similar cases before. Operate according to the maintenance case and replace the controller board. The fault is still the same. 2) Check the connection between the SOP screen and the host, and plug the wiring harness again. The fault remains. 3) Replace the SOP screen, and the fault remains. 4) Replace BICU, imaging IOB board and paper transfer IOB board in turn, and the fault remains. 5) After replacing the DC power board, the fault is solved. Solution Replace the DC power supply board and solve the fault. |