Background of fault occurrence: MP7503 is in normal use and currently has a count of 2.3 million. In the past half month, there have been frequent irregular paper jams accompanied by functional failure prompts. After restarting the device, it returns to normal, but the frequency of failures is increasing, so it is reported for repair! Preliminary remote judgment approach: Due to the rainy and humid environment in summer, it is considered that the paper was affected by moisture, which caused this malfunction. After asking the customer to replace the paper (unpacking), the malfunction still persists; On site handling: Upon arrival at the site, the fault code was found to be SC663-00, which was not found in the manual. After checking the technical platform case, the problem was solved by replacing the IOB board. Therefore, the IOB board was replaced and the connecting harness was checked, and no abnormalities were found. The fault was not resolved during testing; Later, the motherboard and control board were replaced and the fault persisted. Rules for finding faults:It was found that every time the SC663-00 code is reported, there is a paper jam fault, and the location is in the drum unit and fixing unit. So the entire machine wiring was checked and no abnormalities were found. Then, WD40 was used to remove rust from the wiring harness plugs and sockets, and paper was used to dry them and reconnect them for power on testing. The code SC440-01 was found to be faulty during testing of the transfer belt and frame compared to the same model. Later, the code SC440-02 was reported again, indicating that the transfer power board was damaged due to experience. Test the normal operation of the transfer unit using other machines. After half a working day of testing, replace the transfer power board of the faulty machine. After two days of testing, the fault did not occur again. Problem solved. Additionally, you can clean the rod on the transfer printing rack first. Cleaning it thoroughly and testing it can sometimes also solve this code Problem Summary:The fault code may be caused by other codes not reporting properly. The starting point to solve the problem is to eliminate the fault rules and conduct targeted testing based on the characteristics of other faults; It is important to consider whether there is corrosion or oxidation in the connecting wires when the machine is used for a long time in a poor environment. |
Tags: #SC663-00 #SC440-02 #7503 #6503 #Transfer printing power board