Symptoms The MP6002 print appears light and blurry. Reason There is a layer of dirt adhering to the drum, which causes printing problems. After cleaning, the problem was resolved. Maintenance process 1. The fault phenomenon is that the printed product appears light and blurry; After communicating with the on-site CE, it was found that the fault was resolved after replacing the single drum, but the maintenance time was relatively short and far from reaching the PM cycle 2. Observe the usage environment. The machine is stored in a 10 square meter room, which has AF2075 in addition to the faulty machine. Ricoh machines are equipped with paginators, as well as a large number of other computers and accessories; There is almost no space between the machine and the wall; Small workspace without ventilation equipment; Personnel entering the room clearly feel that the temperature is higher than in the hallway and there is no ventilation; 3. When the work status is printing, it is common for customers to load a large amount of homework onto the machine after work and then retrieve it the next day when they return to work; When doing regular homework, it is also necessary to wait for a period of time after sending the homework before taking it out, and when the machine is printing, the room door is closed, which means there is no ventilation environment; 4. Compared with a normal single drum, there are a large number of attached objects on the surface of the faulty drum, causing the printed product to become blurry; Determine that the attachment is formed by substances such as ozone that cannot be discharged from the enclosed machine in the working environment and adhere to the surface of the drum; 5. Upon checking SMC data, it was found that all fans around the drum unit were set to off. Therefore, after turning on all fans and testing approximately 50 faulty single drums, no fault recurrence was observed; After replacing the drum with a new one, it was tested and used normally. Solution Troubleshooting after changing the following settings: SP2972 (color powder bottle cooling fan drive control) is changed to 1; SP2974 (PCU cooling fan drive control) is changed to 1; SP2975 (main intake fan drive control) is changed to 1; SP2976 (developing fan drive control) is changed to 1; Change SP2977 (main exhaust fan drive setting) to 1. |
Tags: #7502 #6002 #Light color #Blurred #9002