Ke Mei's 235 carrier is at the beginning.

Visitor 256 0

ke mei 235 replacement new sets of drum method:

After replacing the drum set, the carrier must be initially used. The method is as follows:

Carrier debugging steps into the lower
1. Open the front door of the machine, take out the toner bottle, and close the front door of the machine.
2. Start up → Press the system menu (or utility) key in sequence quickly → Press the stop key → 0 → 0 → stop key → 0 → 1 to enter the maintenance mode.
3. Press the down arrow to find the FUNCTION (function) → press OK;
4. Press the down arrow to find TCR AUTO ADJUST → press OK;
5. The machine automatically runs for 3-5 minutes and stops automatically, and a numerical value appears (the numerical range should be normal between 120 and 160).
6. Turn off the machine and restart the normal copy to check the effect. The effect is normal. The toner can be used normally.


Leave a comment