1 bizhub 12p (Both A and B methods can achieve zero reset of the powder box) 1. Open the front door cover, remove the consumable components, press start once, insert the consumable components, press start once (standard powder compartment) or twice (high capacity powder compartment), and close the front door cover. 2. Turn off the power,Open the front door coverPress and hold the start button (do not release) to turn on the power until there are three lights on, release the start button (indicator light off), press the start button twice (three lights on), press the start button 6 times (standard powder bin) or 7 times (high capacity powder bin) (indicator light off, error light on), and close the front door cover. As shown in the figure below: After pressing the start button twice, the machine appears as follows:
After pressing the start button 6 times again, the machine appears as follows:
2、 Drum count reset (when the machine's selenium drum light is on)
Open the front door, hold down the GO button until all indicator lights are on, release the GO button, and close the front door cover |
Bizhub 12p (Ke Mei 12P) Powder Clearing and Selenium Cartridge Clearing Method
305
0