1、 ADF installation precautions: When installing DF-628, please select: Maintenance Mode ->System 2->ADF ->"Single sided Scan Send". If "Double sided Scan Document Feeder" is selected, upgrading firmware higher than GXX-28 will report code "C6001". IIThis series comes standard without a hard drive and cannot achieve functions such as USB scanning and printingTo access this feature, an optional hard drive needs to be added. IIIDo not open the hard drive option without installing the hard drive It is possible to experience a system crash and fail to enter safe mode. You need to enter maintenance mode from the fault reset interface (press and hold the reset button to turn on the device). System 2->Hard Drive ->Select Not Installed, then turn off and turn on the device 4Carbon powder bottle capacity setting Item 13 of the installation manual requires setting the capacity of the toner bottle. First, in Maintenance Mode ->System 2->Software Conversion Settings, set HEX with conversion number 59 to 01. Subsequently, in the maintenance mode main menu interface, enter the safety mode (stop - "0" - "C"), where an additional item will be added. Set it according to the manual and consumables type. 5、 If the user feedbacks that the response speed of the operation panel is slow, the firmware can be upgraded to GXX-54 version |