On-site description: The equipment tripped SC220-04; the issue persisted after a restart. Replacing the laser, IPU board, and wiring harness also failed to resolve the problem. Finally, replace the EEPROM on the BCU board, and the repair is complete Maintenance process: the customer reported the paper jam of the document feeder to be repaired. after the customer solved the problem, it was found that when a user used the equipment on site, the document feeder was closed with great effort. after the equipment jumped SC220-04 and consulted the maintenance manual, the laser unit was checked first according to the manual, whether there was condensation on LDB was checked, and the hexagonal prism was cleaned, but the problem could not be solved. Subsequent reconnection of the joint between the LDB and the IPU failed to resolve. The laser was replaced afterwards and was not resolved. IPU replacement did not resolve the issue. Replace the power board, not resolved. At this point it was suspected that there was a problem with the connecting harness between the LDB and the IPU, and the problem persisted after the replacement. Based on previous cases, begin by checking the front door switch and the side door switches. From the SP5803 internal test, it was found that the front door was not closed all the time. After the machine was disassembled, a spring was found to fall off. After the spring was reset, the code disappeared and the SC442-00 appeared. After the transfer belt unit was reset for many times, the SC442-00 disappeared and the equipment jumped SC220-04 again. Then the short circuit of the connecting wire harness was checked and everything was normal. Finally, the teacher suggested to replace the EEPROM of BUC board. After obtaining the new EEPROM, the equipment interface for the first time, after the exchange test, confirm that the BCU board is in good condition, then install this ROM on other normally used equipment, change the serial number, reinstall it on the faulty machine, and replace the flat cable. The equipment can be started normally, the code disappears, and the operation is normal.
|
300
0
Address of this article:https://073868.com/post/6067.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleRicoh MP3353SP exit paper jam