Ricoh Pro8200 boot code SC670-00 SC590-09 SC544-02 SC665-04

Come back soon. 387 0

Symptom: 1. After the machine is turned on, it randomly reports codes such as SC670-00 SC590-09 SC544-02 SC665-04 (as shown in the figure)

Reason: From the literal meaning of the code, it seems to be related to IOB. In fact, the real reason is that BCU and CNB cannot establish communication directly, which leads to the inability to feedback data to IOB (as shown in the figure), resulting in jumping code


Solution:

1. Check the BCU and CNB connection cables (as shown in the figure)

2. Check if the metal sheet of this cable is oxidized or damaged. If it is oxidized, carefully wipe it with a rubber (as shown in the picture)

3. If it still doesn't work, replace this cable. Summary: This type of malfunction is more likely to occur in poor customer environments, humid conditions, or when the water used in the humidifier is tap water, resulting in excessive alkalinity and oxidation of some metal contact points.

Note: Cable ID: D1495387

Tags: #SC670 #8200 #SC590-09 #SC544-02 #SC665-04