HP M177FW printing part is very light, replaced toner cartridge and photosensitive drum invalid

Visitor 347 0
Failure phenomenon: M177FW indicates that the printing part is very light, and the replacement of toner cartridge and photosensitive drum is invalid. The power-on printing test found that the font on the right side of the paper is really light and regular from top to bottom, as shown in Figure 1 (Figure 1)

Adjustment process:
       In the previous maintenance, there were also problems of printing fading, such as CP1025 M176, etc., which were fading in the middle of printing, but it was usually caused by the deformation of the iron sheet in the drum chamber. Check that the iron sheet inside the machine is normal and the fading font of the machine is on the right side of the page, so I consulted the general control and suggested to see if the toner drum roller gear was misaligned and caused abnormal printing, after the disassembly test, the adjustment was indeed caused by the misalignment of the right gear. The readjustment and printing test were normal. The specific adjustment method is as follows:

If we want to adjust the gear, we must first disassemble the machine to find the gear position that needs to be adjusted. The left gear of the machine is relatively easy. Here I will focus on sharing the disassembly process of my right gear. First, remove the ADF above. The side covers and upper panels on both sides can see a motor and sensor on the right side of the machine as shown in Figure 2:

Remove the motor and the sensor beside it, and enter the drum gear cover (the right track of the toner cartridge). As shown in Figure 3 below, remove the large screw and push it to the outside of several circles to get the toner cartridge track as shown in Figure 4.

After removing the toner cartridge track, we will see the toner cartridge roller gear that we need to adjust,
Check the engagement between the gears of the lower roller as shown in Figure 5.

Manually rotate the gear to see if the two red circles in Figure 5 can engage when rotating,
If the occlusal side is normal, if not, the side needs to be readjusted.
We can remove the half-opening gasket (where the red arrow points) next to the white gear as shown in Figure 6 below.

Then you can move the white gear to the left and then manually rotate the large black gear a little bit so that the black and white gears can engage normally to achieve the adjustment effect.

Note:
After adjusting the gears, the whole machine does not need to be reset immediately. First, check whether the card pieces of the security toner cartridge on the black large gears on both sides after adjustment are on the same horizontal line as shown in Figure 7. If the card is not on the same horizontal line side, the roller gear needs to be readjusted, otherwise the toner cartridge will not be properly put into the toner cartridge after the machine is assembled. As well as the sensor gear that we removed in Figure 3 above, we should also pay attention to the alignment of the lower gear. This method can also be used for CP1025, M175, M176 and other models of debugging.