MP_2555SP_3055SP_3555SP_4055SP_5055SP_6055SP Ricoh MP3055 drum cleaning waste powder recycling spiral frequent damage The MP3055 model currently has about 300000 counters. Recently (within 30000 counters), there have been many incidents of the waste powder recovery spiral under the drum cleaning blade popping up and damaging the OPC drum. 1. When the failure occurred for the first time, the engineer found on-site inspection that the toner accumulation under the cleaning blade was serious. The waste powder box is full. Subsequent replacement of waste powder box, photosensitive drum and waste powder recovery screw, copy test is normal. 2. The customer uses about 3,000 copies, and the above-mentioned faults are occurring. The on-site inspection found that the waste powder in the waste powder box is very small, but the clean, recycled and replenished powder in the PCU unit accumulates again. In addition to cleaning the PCDU unit on site, the waste powder transmission channel between the PCDU unit and the waste powder box shall be thoroughly cleaned and the relevant parts shall be confirmed to be free from damage. The image shall be normal after the relevant parts are replaced and adjusted. 3. The customer used about 3,000 more copies, and the same failure occurred for the third time. Link: https://pan.baidu.com/s/1MESaeh79ErZq1SmrNGPWng Extraction Code: dotx After copying this content, open Baidu's internet disk mobile phone App, which is more convenient to operate. Diagnostic process: 1. The on-site inspection found that the waste powder under the cleaning scraper in the PCDU unit is seriously accumulated, which is consistent with the previous two times. 2. Based on the last on-site treatment, re-check the waste powder transmission channel between PCDU unit and waste powder box. It is found that the waste powder is deposited at the entrance of the transfer channel, and there is no waste powder downstream of the channel, which indicates that the waste powder in the PCDU unit has been transferred outward through the recovery screw but the middle transfer channel fails to transfer the waste powder to the waste powder box. The fault parts are concentrated in the waste powder transmission channel unit. 3. Disassemble the waste powder transmission unit, and no abnormality is found by manual rotation. |
Tags: #waste powder #Screw rod #2555 #3055 #4055