MPC2011SP start-up abnormal sound, shut down after reporting SC442-00 Cause analysis 1. MPC2011SP the maintenance manual. See the table below for the SC442-00 code reference solution.
2. Check the ITB unit lifting sensor and trigger, ITB lifting motor, etc. according to the above table, and observe the ITB unit (the transfer belt is not removed), and no abnormality is found. 3. Install the ITB unit again and turn it on. The fault remains. After pulling out the ITB unit, it was found that the ITB unit was abnormal.
Figure 1
Figure 2 Figure (I), the transfer belt drive gear is out of position and the drive bearing is out of position. In Figure (II), the edge of the transfer belt is broken. Based on the above image analysis, the reason for reporting the SC442-00 code is that the ITB lifting sensor cannot be triggered within the specified time due to the abnormal transmission of the transfer belt driving part. The possibility of deformation of the support inside the ITB unit is not excluded. Solution Suggestion: (1) Fully check the internal and external structures of the ITB unit, find out the reasons and eliminate them, reset all the relevant transmission bearings and gears, and replace the transfer belt. (2) Replace the ITB unit assembly. Note: For this kind of failure phenomenon, it is recommended to fully check the ITB unit to find the reason before repairing it to avoid secondary loss. |