Symptoms 1. One MPC2504EXSP has no display or any action when turned on; Possible causes: PSU (AC controller board) fuse disconnection/PSU (AC controller board) fault/PSU (DC board) fault/disconnected connection line/ICU board/MCU board/controller board/short circuit at a certain point; Maintenance process 1. The multimeter measures that the power fuse is normal, the PSU AC and DC interface outputs are normal, and the connection wires for the DC output are normal. The power input problem has been ruled out; 2. Determine if there may be a short circuit phenomenon, and troubleshoot by unplugging the wires on the IPU board and BCU one by one. Remove CN574 from the IPU board Can be turned on later; 3. Check the point-to-point diagram of CN574 connected to the paper transport IOB board CN164. The measurement of the connection line is normal, but the fault still persists after replacing the paper transport IOB board and replacing the IPU board; 4. Pulling out the CN586 from the IPU board can start the machine. Check the point-to-point diagram and connect the CN586 to the laser CN13 (polygon mirror motor). The measurement shows that the connection wire is normal. After replacing the polygon mirror motor, the machine starts normally; Solution Replace the polygon mirror motor and troubleshoot the issue; Note: The polygon mirror motor in the parts manual does not have a separate part number. Please replace the laser unit; |