Ricoh 8120 equipment is abnormal and loud when running, normal in energy saving mode

Visitor 326 0
Symptom: 1) Abnormal noise during device operation, loud sound, normal in energy-saving mode

Reason:
1) Internal gear wear leads to loose meshing and friction noise during operation;
2) Severe bearing wear causes poor operation
3) Fan malfunction

Solution:
1) Open the front door, and the sound is roughly coming from between the developing chamber and ITB;
2) It can be distinguished from the sound that this abnormal noise is caused by a fan malfunction;
3) Using output inspection method for testing, abnormal noise appeared when testing SP 5805-17;


4) Remove the fan
5) Found a lot of dust accumulation inside the fan, clean it up.



6) Cleaning completed, reinstalled for testing, everything is normal.

Tags: #Abnormal noise #Fan #8120 #8110 #Developing