Symptoms After installing a new IMC2000 machine, a green background appeared on the scanned copy, but the printing was normal and the copying fault was the same; Fault sample diagram:
Possible causes: CMOS unit malfunction/setup issue/PCB issue (BICU/engine IOB) Maintenance process 1. Upon on-site inspection of the malfunction, the machine showed a green background pattern during both copying and scanning in full-color mode, indicating normal printing; 2. The full-color scanning image in ACC cover mode of the scanner is normal, but the scanning fault in DF mode still persists; 3. Execute SP4-609-02/4-610-02/4-611-02 to adjust the RGB gray balance in DF mode, but it is invalid; 4. Perform DF concentration adjustment on SP4-688-1, adjust the concentration value to "80", and scan the image normally; |