Symptoms The machine encountered a fault code SC370-00 during startup. Reason The ID sensor connection harness of machine 1 is poor. The ID sensor of machine 2 is dirty or faulty. The ID sensor shutter electromagnet of machine 3 is faulty. The ITB image transfer belt of machine 4 is defective. The drum surface of machine 5 is poor. The motherboard BICU of machine 6 is faulty. Maintenance process On-site maintenance measures: 1) Check the ID related wiring harness on the machine, inspect and clean the ID sensor, ITB unit, and drum surface. The fault cannot be eliminated by starting the machine for detection. 2) Replace the ID sensor, ITB unit, drum sleeve, and motherboard BICU of the machine. The fault still exists. 3) Enter maintenance SP50804-21 to test that the electromagnetic shield does not move. Replace the electromagnetic shield and ID sensor of the machine, and troubleshoot the issue. (Note: After removing the ID shield electromagnet and cleaning the axis, the test was normal. The ID sensor optical head was found to have scratches. Only by replacing the ID sensor can the fault be resolved)
Electromagnetic shielding plate
ID sensor Solution Clean the electromagnetic shield and replace the ID sensor, the machine is functioning properly. |
388
0
Address of this article:https://073868.com/post/5582.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleRicoh M 2701 startup error code SC350-00