Ricoh MP5054 Copy A3 has a row of text compressed and reduced in size in the middle

Visitor 277 0
Symptoms
The printed matter is compressed in the sub scanning direction (A3 paper), and the frequency of occurrence is not fixed, which is occasional.


Analysis process:
Due to occasional occurrence, the faulty image on the drum cannot be seen during the production of the cardboard, and only replacement parts can be tested.
  • After replacing the fixing unit and testing continuously for one week, faults will still occur.
  • The sensors and paper rollers of each unit in the cleaning paper path are still faulty.
  • Replace the drum, scraper, and carrier separately, but the malfunction still persists.
  • The PCDU unit was replaced and tested continuously for one week, and the fault did not occur.
  • Replace the developing unit for testing and troubleshoot.
Solution: Replace the developing unit and troubleshoot.