Ricoh DD5441C,5451C printing cylinder often fails to hang plate paper.

Visitor 305 0
Symptoms:
The DD5451C machine's printing cylinder often fails to hang the plate paper, and even if it is hung, the plate clamp rarely clamps the plate paper
As shown in the following figure:



Clamp the board clamp to the paper state (the board head is shorter)


Comparison of Normal and Abnormal Length of Paper HeadReason:Poor clamping of the printing cylinder platePlate-making department plate paper guide plate bad;Wear of printing cylinder drive gearLoose main drive gearMaintenance process:1, on-site inspection printing cylinder plate clamp opening and closing is normal, no abnormality;2. On site inspection of the plate paper guide plate in the plate making department, no abnormalities were found;3. After checking the feeding situation of the plate paper bin, no abnormalities were found. It is still suspected that the position of the printing cylinder is not in place, causing the plate clamp to be unable to correctly clamp the plate paper head. The teeth of the printing cylinder were checked and no abnormalities were found. The main drive gear was checked and found to be loose. Gradually, it was found that the screws on the drive gear were loose. The screws were re fixed and the plate making test was started up. No faults were found to recur, and the machine was tested normally.As shown in the figure:      


Solution:Fix the screws of the main drive tray, troubleshoot, and the machine test runs normally.

Tags: #5441C #5451C #printing cylinder #Unable to hang the paper board