Ricoh Pro 8300S, 8310s, 8320s installation instructions, firmware upgrade

Visitor 348 0
【Installation Inspection Checklist】        ※ Compare the installation environment survey form again, check each basic item, and confirm the power capacity of the host and the required power sockets for sockets and accessories
Please prepare the latest firmware and paper library files, The paper library files for various models of Baron-C3 are not universal. It is necessary to prepare paper library upgrade files according to the model
When opening the packaging, the accessories must be counted and properly stored before and after installation. To avoid being unable to operate due to loss during future use and maintenance.
<开机前准备><Note> 4-1 □ Install panel support, operation panel, and warning light * (note the order of the back cover) 4-2 □ Install the fixing roller handle bracket, remove the ITB fixing rod, and store the ITB and fixing lamp positioning tools 4-3 □ Install rear exhaust duct filter 4-4 □ Pull out the lower paper tray, check and adjust the level of the host to 2.5mm/1m4-5 □ Connect the power supply and test the circuit breaker4-6 □ Turn on the operation switch and set the administrator password. Turn off the power.4-7 □ Turn on the main power and keep the left front door openAfter sufficient shaking, install 2 toner bottles and keep the left front door open
<开机初始化><Note> 5-1 □ Enter SP mode and executeSP7628-002,Exit SP method5-4 □ Prepare firmware and model paper library in SD card,
5-2 □ Close the left front door and wait for the ready prompt5-5 □ Shut down, insert SD card into SD slot 2, upgrade firmware and import paper library
5-3 □ Enter SP mode and check that the process control result of SP3012-001 is "11".       ExitSP method.5-6 □ Check SOP system and APP, upgrade if necessary
< 调 整 ><备注>Host6-1□ SP5824 backup NVRAM, SP5992-0, export SMC data6-2 □ Print graphics and check image quality

unrolled unit
7-1 □ The unwinding unit is padded on both sides, and the connecting hooks are fixed with M4x8 screws7-4 □ Close the front door and execute SP5804-128
7-2 □ Correctly install downstream equipment connection guide plate (* see note)7-3 □ Input random parameters into SP1927-001 and SP1928-0017-5 □ Execute SP1-906 (Set the unwinding amount of the paper tray)
Large capacity paper box8-1 □ Height adjustment8-2 □ Check horizontal alignment, adjust if necessary, and add shims
Vacuum long paper tray SP5-150-002:1
Hand fed paper table9-1 □ Replace the LCT top cover plate and install the hand delivery table connector or adapter (vacuum paper box)9-2 □ Install the manual paper feeding table and connect the wiring harness
Hand fed long paper tray SP5150-001:1
folding machine10-1 □ Circuit breaker detection10-3 □ Paste polyester sheet on the downstream equipment inlet guide plate
10-2 □ Perform skew and lateral position adjustmentWhen connecting to downstream equipment, M4X14 screws must be used for the lower part of the hook
Stacker11-1 □ Assemble the car11-2 □ Perform skew and lateral position adjustment
Final processor12-1 □ Remove the fixed components and inspect the circuit breaker12-3 □ Perform skew and lateral position adjustment
12-2 □ Lower the binding paper tray casters
*guide plate"A"Folding unit, cover insert tool guide plate"C": Pager
Fiery EB35Install a gigabit network card. Set up an external print server , inComplete the setup on Fiery.• SP5-193-001: [1]• SP5-985-001: [1]• SP5-895-001: [1]• SP4-201-005: [15]• SP4-201-006: [15]• SP4-201-011: [1]• SP4-201-012: [1]
Set counting method: ConfirmSP5045-1:1The billing method is fixed atA3=A4SP5104-001:0
Long paper mode enabledSSP5104-101:1SSP5104-102:412
Billing threshold
Hand delivery extended to700mm :SP5150-001:1
Expansion of vacuum paper box to700mm:SP5150-002:1


Firmware Upgrade Instructions
Host firmware:
1. Regular firmware files
Run the self extracting file to obtain*. fwu firmware file
  SD:\ROMDATA\xxxxxxx1A.fwu
    xxxxxxx2A.fwu
2. Integrated firmware package PKG file (can include SOP file)
  SD:\PACKAGE\xxxxxxxx1A.pkg
If the system cannot recognize itPKG file, please use decompression software to gradually decompress the PKG firmware package to fwu format, and prepare the SD card according to method 1
Upgrade will be doneInsert the SD card into the maintenance slot,Close the front doorUpon startup, select the upgrade option based on the panel prompts

SOP system upgrade:

Operation panel startup methodset as ordinary ,( fast Method cannot enter recovery mode <见SOP特殊关机步骤>)
Recovery mode(Recovery Mode)hold down[Stop button]and[#]BootAfter the screen turns white, release it[#]hold down[Start button]
Operations in recovery mode:Stop  upward

Startdown

#Confirm
SOP firmware preparation: Place the operation panel firmware xxxxxxxx.zip into the root directory of the SD card, (SD:\package\xxxxxxx.pkg)
Enter recovery mode selection'Apply update from sdcard' upgrade
SOP application software installation: SD: \ APP \ xxxxxxx.zip
Enter the keypad,Reset 806182 # # Stop, enter SP mode of SOP to install APP

SOP special shutdown steps
wayUsagemethod
Normal shutdownDaily user shutdownHost power button
Force shutdownThe host cannot shut down normallyhold down power button 6 seconds
Replace components and shut downNeed to unplug and replace componentsPress and hold the 'Stop' button to turn off the power button


Software upgrade shutdown
Do not change the screen startup modeRecovery Mode Upgrade Panel Firmware

Press and hold【#Turn off the main power supply

Tags: #8300 #8310 #8320 #Firmware Upgrade Method

Leave a comment