E778XX machine reported error 63.00.3B, 63.00.3D, 63.00.3F, or 63.00.41 Reason: 63.00.3B yellow toner replenishment error, 63.00.3D magenta toner replenishment error, 63.00.3F cyan toner replenishment error, 63.00.41 black toner replenishment error The printer detects the toner concentration in the developer is too low or depleted by the T/C sensor. Troubleshooting ideas: 1. check the machine firmware version and upgrade the printer firmware to the latest version 2. check whether the powder box is normal 1. Remove the toner box and shake the toner box many times to ensure that the toner in the toner box is not agglomerated. 2. Open the powder outlet of the powder box to ensure that the seal of the powder box is clean and there is no foreign matter or powder agglomeration blocking the powder outlet. Manually rotate the toner box gear clockwise to check whether the powder screw rod (the arrow on the left points to the part) inside the powder box can rotate normally and confirm whether the powder box can normally powder. If there is any problem with the powder box, please replace it with a new one.
3. check whether the powder motor is normal Enter the Support Tools support tool-Service service (login password: 04077817)- Service Tools service tool-Diagnostics- Engine Diagnostics- Engine Test Routines to manually test the powder motor of the corresponding color to confirm whether the powder motor rotates normally. when testing the powder motor, it is necessary to take out all powder boxes, close the front door, and then perform the powder motor test, otherwise the powder motor does not move 111-0030, black powder motor 111-0020, cyan powder motor 111-0010, magenta powder motor 111-0000, yellow powder motor If the powder feeding motor does not rotate, please check and judge whether the plug/powder feeding motor/24v power supply (power board)/main board is faulty according to the instructions of CPMD manual. 4. check whether the lower powder pipe is normal 1. Check whether the powder switch of the lower powder tube is normally open. The following figure shows the normal open state
|
Tags: #E77822