iR-ADV C5535 iR-ADV C5540 iR-ADV C5550 iR-ADV C5560 iR_ADV C5235 iR_ADV C5240 iR_ADV C5250 iR_ADV C5255 iR_ADV C5030 iR_ADV C5035 iR_ADV C5045 iR_ADV C5051 Error code E027-0x00 and E021-0x00 countermeasures due to broken coupling stop. [Failure Phenomenon] Prompt error code E027-0x00 and E021-0x00 -E027-0x00: Development assembly supply error (x = 1:Y, 2:M , 3:C , 4:Bk) -E021-0x00: Development motor error (x = 1:Y, 2:M , 3:C , 4:Bk) [Cause of Failure] After the equipment has been used for a period of time, a hole [a] appears on the surface of the coupling stop [2] on the main drive unit [1] due to repeated friction of the parallel pin [3]. In this case, if the parallel pin [3] falls through the hole, it will cause the main drive unit [1] to fail to operate and the above error code will appear.
[Maintenance measures] When the above failure phenomenon occurs, please prepare and replace the new type of coupling stopper (FC8-4171-010)[B]. The material of the new model coupling stopper [B] has been changed, and the durability of the parts has been improved. In combination with the change in the material of the part, the color of the old model part is also changed from black to white as shown in the figure below.
|
371
0
Address of this article:https://073868.com/post/5091.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleCanon C5560 tips E602-1402 repair methods
NextHP High-end Color Machine Code 59.F0 No Spare Parts Graphic Solution