Overview: Occasional internal failure 043-349 (exhaust fan rotation failure) occurs on Botan medium high speed models with a large number of copies output. Failure phenomena and causes: As shown in the following figure, the exhaust fan (PL4.1 Item13) and the right front exhaust fan (PL4.1 Item9) originally configured in the IOT of Botan medium and high speed models have not been configured again in order to reduce the operating noise of the machine.
When the NVM value of the machine does not match the fan setting, the rotation of the two fans is still detected while the machine is running, resulting in an internal fault 043-349. Solution: In Engineer Mode, enter Diagnostics to confirm or change the following three NVM values: 741-112:272 → 278 (fan action control) 741-132: 0 → 1 (exhaust fan control) 741-160: 0 → 1 (right front exhaust fan control) Precautions: Botan low speed models do not have such problems. |
340
0
Address of this article:https://073868.com/post/5062.html
Copyright Notice:
For relevant infringements, reports, complaints and suggestions, please send E-mail:weixiuwang68@qq.com
Previous articleCOUNTERMEASURES TO NOISE FAULT IN EXPORT I AFTER Massive EXPORT of Xerox VII C7773
NextCountermeasures for Xerox VII C7773,C4473,C2273 A2 Stapler 012-283