COUNTERMEASURES TO NOISE FAULT IN EXPORT I AFTER Massive EXPORT of Xerox VII C7773

Visitor 319 0
Countermeasures for ApeosPort/DocuCentre-VII C7773/6673/5573/ 4473/3373/3372/2273 Noise Failure Caused by Large Output
Overview:
As shown in the following figure, when the machine outputs about 100 copies, the cover plate of the second component of the outlet is deformed by heat, and the bottom interferes with the surface of the first roller of the outlet, thus making friction noise.


Solution:
Between the outlet second cover plate and the outlet first roller, a spacer is interposed to prevent interference therebetween.
As shown in the figure below, after installing this spacer, the gap between the second outlet cover plate and the first outlet roller is maintained. Even after the machine outputs a large number of copies, the internal temperature of the second outlet rises, the second outlet cover and the first outlet roller will no longer interfere with each other, thus avoiding the generation of noise.




Tags: #c7773 #c6673 #c5573 #C4473 #Noise