Xerox DW6050,6030 repair cases

Visitor 369 0
  • DW6030 DW6030 03-205 Solutions
  • Measures to DW6030_6050_TI040(FTI3-AP034)IIT IIT Firmware Version 3.0.0 Clients
  • Problems after replacing IOT IF PWB and FLASH ROM
  • DW6030 DWScan II Scanning Software Naming for Batch Scanning
  • DW6030/6050 printout drawings will have some deviation in length from the set length
  • Information DW6030_6050_TI028 the (FTI3-AP026) Error Code List
  • DW6030_6050_TI029(Unique)Appendix Fuser Temperature Setting Accessory
  • DW6030_6050_TI029(Unique) Fuser Temperature Setting
  • Recovery procedure if the DW6030_6050_TI030(Unique)IIT control panel firmware upgrade fails
  • Introduction of DW6030_6050_TI031(FTI3-AP027)MOT_DRIVER_PWB Protection Circuit
  • DW6030_6050_TI032(FTI3-AP028)CP-Cont Firmware Version Upgrade Information_V2_
  • DW6030_6050_TI032(FTI-028)AppendixCP-Cont firmware version upgrade information
  • DW6030_6050_TI033(FTI3-029AP) Waste Powder Bottle Full Re-setting Inspection
  • Countermeasures for DW6030_6050_TI035(SB1-004AP) uneven concentration
  • DW6030_6050_TI036(SB1-AP005) Improved E-Tra Code Heap Performance
  • DW6030_6050_TI037(FTI3-AP030) Information on changes to the fuser-1st
  • DW6030_6050_TI038(FTI3-AP031) Information on Changes to the Fuser-Section 2
  • Measures to DW6030_6050_TI040(FTI3-AP034)IIT Firmware Version 3_0_0 Client
  • Introduction to DW6030_6050_TI041(FTI3-038)IOT Firmware V3_1_02
  • DW6030_6050_TI041(FTI3-038)UpgProcIOT Firmware V3_1_02 Edition Upgrade Note
  • DW6030_6050_TI042(FTO2-AP002) Emergency Boot DVD Drive
  • DW6030_6050_TI043(FTI3-AP035) Measures for Noise Problem when Power on
  • DW6030_6050_TI044(FTI3-AP036) Shims for reducing clearance at the end of the mandrel
  • DW6030_6050_TI045(FTI3-AP037) Modification of the Housing on the Developer Assembly
  • DW6030_6050_TI046(FTI3-AP039)Appendix1 upgrade CP-Cont firmware to 2
  • DW6030_6050_TI046(FTI3-AP039) upgrade CP-Cont firmware to 2_3_15
  • Improvement of Fuser Clamping Cam by DW6030_6050_TI047(FTI3-AP040)
  • DW6030_6050_TI048(SB1-AP006) Measures to Burrs in Protective Cover of Cutting Knife
  • DW6030_6050_TI049(FTI3-AP044) Optional Stacker Tray Installation Procedure
  • Countermeasure of DW6030_6050_TI052(FTI3-AP043) Fixing Guser
  • Countermeasures for DW6030_6050_TI052(FTI-043)Appendix Fixing and Reprinting Attachment
  • DW6030_TI200705022 the problem of dragging the end of the copy when making imposition copies.
  • Solution to 03-205 in DW6030
  • DW6030 can not boot (no UI display, the machine does not start)

Processing:1. Check that the power cord 220V is normal and BSD CH1.1 T1/T2/T3 has 220V.2. BSD CH1.6 LVPS24V-A input and output are normal.
3. BSD CH1.2A MAIN RELAY output 220V is normal.
4, BSD CH1.3 LVPS RELAY no output check the relay is normal
It is judged that IOT IF PWB is faulty, and it still cannot be started after replacement.
Check the power supply LVPS ESS PWB of IOT IF PWB. The PWB component is burnt out and can be started after replacement. However, after a few seconds after the machine is started, the user's power supply trips when it is empty, and the machine does not jump when it is empty. Because the machine did not jump when it was empty, it was suspected that the user's empty power was too small. If more power was replaced, it still tripped, and the machine did not jump when it was empty. To eliminate the problem of users opening empty, there should be a short circuit inside the machine.
To find a short circuit:
1. Disconnect the 220V load of the machine and connect it one by one.
2. After disconnecting the fixing power supply, it can be started without tripping. The next part will find out which part of the fixing caused the trip. 1) Unplug the thermal sensor and do not trip. 2) Unplug the fixing lamp power supply and trip
3) Fixing is all connected. Open the front of the machine (disconnect the 24V interlock). Unplugging the thermal sensor without tripping and opening the front of the machine will cause the machine to disconnect the fixing power. Check the BSD CH10.2B FUSER RELAY and find that the FUSER RELAY is short-circuited. After replacing the RELAY, the machine starts normally. (There is a PAPER HEATER RELAY next to FUSER RELAY. Both are the same, because PAPER HEATER does not have it, so it can be used for emergency.)
As long as the IOT chain switch, there is any open circuit, the fixing will not heat up. The high-power parts of the machine are fixing lamps (large power consumption), so the possibility of causing an open trip is greatest. In addition, in this case, the break of the machine did not jump, but the user's open trip. The possible reason is that the safety current at the user is less than that of the machine.
  • DW6030 Large amount of image loss when copying
  • When DW6030 is multiplexed, the copy near the UI output end is obviously shallow.
  • DW6030 Job Cannot Print
  • UI touch screen can only display "X" mark after power on
  • Unable to copy properly after DW6050_TI20070122 replacement of IIT motherboard
  • DW6050_TI20070320 the solution process of 09-905 appears
  • DW6050 Recovery after 03-302 Problem
  • DW6050 appears 09-905 resolution process
  • The problem of image loss at the end of DW6050 when printing long images
  • DW6050 After changing the first print idle time
  • DW6050 and DW3030 Print Centering Issues
  • Fix after DW605030 03-302 problem
  • FUJI XEROX DW6050 Operation Panel Chinese Upgrade Steps
  • H_Local_TI-13003 1-301
  • H_Local_TI-13003 DW6030 6050 1-301
  • Drawings are automatically cut at about 444mm.
  • Limitation of DW6050 Gray Scan Length
  • PS Settings for DW6050
  • When DW6050 is installed, it is found that reading 2 does not count after paper feeding.
  • DW6030 Image Printing Uneven
  • Solution of Crepe Paper for DW6050 Printing Long Chart
  • Unable to upgrade the system using the optical drive
  • DW6050 UI cannot be displayed properly
  • DW6050 appears 09-905 resolution process
  • After installing PDF option, PDF documents still cannot be printed
  • DW6030 DWScan II Scanning Software Naming for Batch Scanning
  • Solution of fault code 08-201 (static paper jam) in DW6030
  • Considerations When Replacing the Controller Board (CP-CONT PWB)
  • Problems after replacing IOT IF PWB and FLASH ROM
  • Fuser temperature setting
  • TI041(FTI3-038) Upgrade Considerations
  • Countermeasure of Fixing Gumball
  • Countermeasures for Appendix Fixing and Reprinting Attachment
  • DW6050,6030 to achieve SCAN to generate PDF format files
  • DW6050 output the same size drawing copy size difference
  • Unable to output 2A0 drawing under DW6050 NADAMS
  • Unable to print under DW6030 Catia V5
  • After installing PDF option, PDF documents still cannot be printed
  • Unable to copy properly after replacing IIT motherboard
  • Fixing temperature setting accessory
  • Correcting errors in DW6050 TI047
  • UI touch screen can only display "X" mark after power on
  • Stepped bottom ash appears on the edge of the drawing when the blueprint is copied.
  • The problem of dragging the tail end of the copy when making a copy.
  • Cyclically weak solutions

AbstractHere is the information for the list of error codes.Content Here are the error codes added after the F/W upgrade, in addition to the error codes included in the first edition of the FXAP Service Manual.
Added error code. For details of the error content that has been added, please refer to the attached error list.

Error codeMeaning
System error06-220Ros On Timing Error Roller 1
06-221Ros On Timing Error Roller 2
06-222Ros On Timing Error Roll 3
06-223Ros On Timing Error Roll 4
06-224Ros On Timing Error Tray 1
06-225Ros On Timing Error Tray 2
06-226Ros On Timing Error MSI
06-227Ros On Timing Error MSI (Manual)
Door/blocking error01-302Door opening/closing
01-303Door Open/RFC-1 Door
01-304Door Open/RFC-2 Door
01-305Door Open/MSI
01-306Door open/E-Tra
07-915Door Open/Tray 3
07-916Door Open/Tray 4
07-920Door opening/RFC-1 device
07-921Door opening/RFC-2 device
07-922Door opening/RFC-1 door buckle
07-923Door opening/RFC-2 door buckle
08-309Paper feed jam/rewind/roller 2 setting
08-311Paper feed jam/rewind/roller 4 setting
08-110Guide along the edge of the jam/tray 3
08-114Guide along edge of jam/tray 4
08-201Paper jam (paper left in the machine)
08-202Paper jam (paper left in machine)/power saving
08-203Paper jam (paper left in machine)/after paper output
07-350Paper jam (paper left in machine)/Tray 3
07-351Paper jam (paper left in machine)/Tray 4
07-454Paper jam (paper left in machine)/ RFC-1
07-455Paper jam (paper left in machine)/ RFC-2
07-361Paper jam (paper left in machine)/ MSI take away
08-204Miscut paper/RFC-1
08-205Miscut paper/RFC-2
Setting error07-999No paper
10-981Heating error
12-301Pager Error

DW6030 Product TOP10 Questions Quick Reference
Serial numberSubsystemProblem DescriptionSolutionReference document
1Electrostatic partPosition random, along the paper direction. And black lines appear before the transferSee IOT Workshop Manual, 3rd Edition, Chapter 3, page P3-25, for a description and workaround of the black line. Most of the problems in the field are caused by the black line problem caused by the dirty or broken blade of the cleaning blade. When the engineer replaces the drum, please replace the drum blade and BCR at the same time to prevent the old parts from wearing out the new parts. After replacing the cleaning blade and drum, be sure to use special talcum powder for lubrication. 
2Controller SystemThere are the following two phenomena: 1. The machine reported error code 03-302. 2. The processing speed of the print job becomes slow, sometimes the job cannot be printed for a long time, and even the machine crashes.Use the F/W rewrite system CP-CONT the CD version of 2.3.15 and upgrade to the latest vervion 4 series using a network cable. See Local TI20070910 for solutions and preventive measures. If there is a problem that Local TI cannot fix, please debug according to Local TI20061103.IBG TI042
Local TI20061103
Local TI20070910
3Electrostatic partIn particular, when a drawing with a large amount of toner is printed, the depth of printing density is uneven.Clean the surface of the magnetic roller and the magnetic roller blade, and remove the carbon powder caking on the surface of the magnetic roller.Local TI20061101
4Fixing partThere are three kinds of phenomena: 1. The error code of 08-200 appears in DC122 in IOT diagnosis. 2. The paper is drilled between the hot roller and the hot roller separation claw. 3. The paper is drilled between the press roller separation claw and the press roller.For case 1: if a large number of 08-200 error codes are found in DC122, please replace the Motion Sensor(PL5.3 Item13 Part No:130E96481) at the fixing outlet. for case 2: please clean all the hot roller separation claws first. if the problem still exists, please replace the hot roller separation claws with problems. if the problem still occurs from time to time, please replace the upper guide plate assembly of the fixing outlet (PL5.3 Item4 Part No:055K30350) For case 3: clean or replace the pressure roller separation claw. 
5Fixing partThe toner of the paper head image sticks to the bottom. Their spacing is 157mm.Please check whether the user's paper settings are correct first. And adjust the fixing temperatureIBG TI052
6Electrostatic partBottom ash in printed copySee IOT Service Manual, 3rd Edition, Chapter 3, Page P3-24, for a description and workaround of the copy bottom ash. 
7Fixing partMostly sulfuric acid paper crepe paper. The fault was mostly intermittent, with one or more obvious creases on the copy.See IOT Service Manual, 3rd Edition, Chapter 4, page P4-25, to adjust the fixing pressure at both ends of the fixing. Check that the paper heating switch is off. Execute IBG TI024 and add star wheel. Replace with better quality paper.IBG TI024
8Fixing partThe toner is easy to be wiped off, and more fixing problems on site are caused by poor fixing pressure.The cam at both ends of the fixing pressure is seriously worn, resulting in the pressure roller can not be fully lifted, resulting in insufficient fixing pressure. Replace the corresponding worn parts.Local TI20071205
IBG TI047
9Fixing partBlack line due to heat roll breakageReplace the damaged hot roll. At the same time replace the hot roller separation grip and thermal sensor. Usually on the fixing maintenance, should pay attention to the separation claw and thermal sensor cleaning. 
10Electrostatic and fixing partCopy has black spotsDetermine where the problem occurs based on the cycle of the black dot. See IOT Service Manual, 3rd Edition, Chapter 3, page P3-20 for cycles. Clean or replace the corresponding parts. 
Link: https://pan.baidu.com/s/1DncxMSVn4g75odNhsHTXsw
[kkpay=20]Extraction Code: tlip[/kkpay]

Tags: #6050 #6030 #Xerox

Leave a comment