Symptoms During the automatic adjustment and testing process of the new machine installation, an unexpected power outage occurred, resulting in uneven alignment of the output sample line during subsequent automatic color calibration. The SP2111 line alignment adjustment failed. Cause analysis The inaccurate color matching caused by uneven line alignment is mainly due to hardware reasons such as laser unit, ITB, ITB cleaning, black PCDU unit, black drum motor, etc. Considering that it was caused by an unexpected power outage during the installation of the new machine, the focus is on the laser unit. Solution: 1. Re download the laser unit data (SP2-110-005) according to the "Laser Unit" section of the maintenance manual for replacement and adjustment; 2. SP2-111-004: Perform line alignment adjustment again and check the execution results through SP2-194; 3. SP3-011-001 executes manual process control and checks execution results through SP3-012 After implementing the above adjustment methods, the fault was repaired. |
Tags: #C3000 #Image misalignment #Positioning #Color