Symptoms: The machine generates the SC670 code when turned on. Analysis of possible causes of failure: 1. The BCU board is damaged. 2. The control board is broken. Measures: 1. Replace the control board. The NVRAM, hard drive, SD card, and memory on the control board are still faulty. 2. Replace the BCU board and IPU board, but the fault persists. 3. No abnormalities were found during the inspection of the wiring harness. 4. Replace the power board and test it for normal operation. Upon inspection, it was found that one of the fuses was damaged. Replace the fuse and test it. The machine will display an SC202 code, and the fuse location is shown in the following figure. Solution: Replace the power board and test run everything normally. |
Tags: #SC670 #6002 #9002 #7502 #Power board