Symptoms The IMC2500 machine cannot enter the normal operation interface when turned on, and then shuts down. (See screenshot 1-3 below) After booting up, it displays "starting up face wait" as shown in Figure 1, and then enters the display screen of Figure 2 for about 5 seconds. After that, the screen displays "shutdown..." as shown in Figure 3, and then the screen goes off.
Maintenance process 1. Firstly, an attempt was made to upgrade the firmware, but the upgrade could not be implemented properly; 2. After replacing the BCU board and controller board unit (including memory and hard disk) of the normal machine at the same time, the faulty machine can start up normally; 3. By replacing the testing methods separately, it was determined that the problem occurred on the controller board unit; 4. Test the controller board (including NVRAM), hard disk, and memory module separately for the controller unit, and ultimately determine that the memory module is damaged. Solution: Replace the memory module on the controller board (Figure 4). |